201 research outputs found

    Using integrating spheres as absorption cells: path-length distribution and application of Beer's law

    Get PDF
    We have modeled the path-length distribution in an integrating sphere used as a multipass optical cell for absorption measurements. The measured radiant flux as a function of analyte concentration is nonlinear as a result, deviating from that expected for a single path length. We have developed a full numerical model and introduce a new analytical relationship that describes this behavior for high reflectivity spheres. We have tested both models by measuring the optical absorption of methane at 1651nm in a 50mm diameter sphere, with good agreement with experimental data in the absorption range 0-0.01cm -1 . Our results compare well with previous work on the temporal response of integrating spheres

    Gas cells for tunable diode laser absorption spectroscopy employing optical diffusers. Part 1: single and dual pass cells

    Get PDF
    New designs for gas cells are presented that incorporate transmissive or reflective optical diffusers. These components offer simple alignment and can disrupt the formation of optical etalons. We analyse the performance-limiting effects in these cells of random laser speckle (both objective and subjective speckle), interferometric speckle and self-mixing interference, and show how designs can be optimised. A simple, single pass transmissive gas cell has been studied using wavelength modulation spectroscopy to measure methane at 1651 nm. We have demonstrated a short-term noise equivalent absorbance (NEA, 1 sigma) of 2x10(-5), but longer term drift of up to 3x10(-4) over 22 hours

    Innovation in Small and Medium-Sized Enterprises: A Study of Businesses in New South Wales, Australia

    Get PDF
    This paper examines the process of innovation within SMEs, focusing on a sample of firms in New South Wales, Australia. The trend of the last several decades towards increased integration of global markets, or globalization, has meant that many firms are experiencing continuously increasing pressure to remain viable as their markets expand, and they begin competing with a larger number of firms. SMEs, in particular, are vulnerable to this pressure, since they tend to be disadvantaged relative to larger firms that generally have better access to funding and other resources. The ways in which SMEs operate to remain economically viable, and contribute to economic performance, is of especial interest to governments given the prominent roles that they play in most economies. One way of doing so is through innovation. In this paper, we present a more complex model of the innovation process than the traditional linear model involving R&D investment, what we term the "Ripple Effect Model", building upon recent developments in the literature. The Ripple-Effect Model appears to be substantially supported.small and medium enterprises, innovation, New South Wales, Australia

    Quantum cascade laser light propagation through hollow silica waveguides

    Get PDF
    In this paper, the transmission characteristics of hollow silica waveguides with bore diameters of 300 and 1000 μm are investigated using a 7.8-μm quantum cascade laser system. We show that the bore diameter, coiling and launch conditions have an impact on the number of supported modes in the waveguide. Experimental verification of theoretical predictions is achieved using a thermal imaging camera to monitor output intensity distributions from waveguides under a range of conditions. The thermal imaging camera allowed for more detailed images than could be obtained with a conventionally used beam profiler. The results show that quasi-single-mode transmission is achievable under certain conditions although guided single-mode transmission in coiled waveguides requires a smaller bore diameter-to-wavelength ratio than is currently available. Assessment of mode population is made by investigating the spatial frequency content of images recorded at the waveguide output using Fourier transform techniques

    Self-mixing interference effects in tunable diode laser absorption spectroscopy

    Get PDF
    We report the effects of self-mixing interference on gas detection using tunable diode laser spectroscopy. For very weak feedback, the laser diode output intensity gains a sinusoidal modulation analogous to that caused by low finesse etalons in the optical path. Our experiments show that self-mixing interference can arise from both specular reflections (e.g. cell windows) and diffuse reflections (e.g. Spectralon™ and retroreflective tape), potentially in a wider range of circumstances than etalon-induced interference. The form and magnitude of the modulation is shown to agree with theory. We have quantified the effect of these spurious signals on methane detection using wavelength modulation spectroscopy and discuss the implications for real gas detecto

    Integrating cavity based gas cells: a multibeam compensation scheme for pathlength variation

    Get PDF
    We present a four beam ratiometric setup for an integrating sphere based gas cell, which can correct for changes in pathlength due to sphere wall contamination. This allows for the gas absorption coefficient to be determined continuously without needing to recalibrate the setup. We demonstrate the technique experimentally, measuring methane gas at 1651nm. For example, contamination covering 1.2% of the sphere wall resulted in an uncompensated error in gas absorption coefficient of ≈41%. With the ratiometric scheme, this error was reduced to ≈2%. Potential limitations of the technique, due to subsequent deviations from mathematical assumptions are discussed, including severe sphere window contamination

    A measurement strategy for non-dispersive ultra-violet detection of formaldehyde in indoor air: Spectral analysis and interferent gases

    Get PDF
    We have conducted an extensive review of published spectra in order to identify a region with potential for detection of formaldehyde in indoor air. 85 chemicals and chemical groups common to the indoor environment were identified, 32 of which had absorption spectra in the UV-vis region. Of these, 11 were found to overlap with the formaldehyde UV region. It was found that the region between 320 to 360 nm is relatively free from interference from indoor gases, with NO being the only major interferent. A method is proposed for a low resolution (3 nm) spectroscopic detection method, specifically targeted at formaldehyde absorption features at 327 nm with a reference at 334 nm. 32 ppb of NO was found to have a cross-sensitivity with equivalent magnitude to 100 ppb of formaldehyde. A second reference at 348 nm would reduce this cross-sensitivity.This work was funded by the Engineering and Physics Science Research Council (EPSRC) under grants GR/T18424, EP/P504880 and EP/H02252X. Enquiries for access to the data referred to in this article should be directed to [email protected]

    Noise analysis for CCD-based ultraviolet and visible spectrophotometry

    Get PDF
    Full-text not yet available due to publisher embargo.We present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise. These were identified and characterized by varying light source, spectrometer settings, or temperature. A number of noise-limiting techniques are proposed, demonstrating a best-case spectroscopic noise equivalent absorbance of 3.5×10−4  AU for the AvaSpec-3648 and 5.6×10−4  AU for the Ocean Optics S2000 over a 30 s integration period. These techniques can be used on other CCD spectrometers to optimize performance

    Formaldehyde sensor using non-dispersive UV spectroscopy at 340nm

    Get PDF
    Formaldehyde is a volatile organic compound that exists as a gas at room temperature. It is hazardous to human health causing irritation of the eyes, nose and throat, headaches, limited pulmonary function and is a potential human carcinogen. Sources include incomplete combustion, numerous modern building materials and vehicle fumes. Here we describe a simple method for detecting formaldehyde using low resolution non-dispersive UV absorption spectroscopy for the first time. A two channel system has been developed, making use of a strong absorption peak at 339nm and a neighbouring region of negligible absorption at 336nm as a reference. Using a modulated UV LED as a light source and narrowband filters to select the desired spectral bands, a simple detection system was constructed that was specifically targeted at formaldehyde. A minimum detectable absorbance of 4.5 × 10-5 AU was estimated (as ΔI/I0), corresponding to a limit of detection of approximately 6.6 ppm for a 195mm gas cell, with a response time of 20s. However, thermally-induced drift in the LED spectral output caused this to deteriorate over longer time periods to around 30 ppm or 2 × 10-4 A

    Sensitive detection of methane at 3.3 μm using an integrating sphere and interband cascade laser

    Get PDF
    Detection of methane at 3.3μm using a DFB Interband Cascade Laser and gold coated integrating sphere is performed. A 10cm diameter sphere with effective path length of 54.5cm was adapted for use as a gas cell. A comparison between this system and one using a 25cm path length single-pass gas cell is made using direct TDLS and methane concentrations between 0 and 1000 ppm. Initial investigations suggest a limit of detection of 1.0ppm for the integrating sphere and 2.2ppm for the single pass gas cell. The system has potential applications in challenging or industrial environments subject to high levels of vibration
    corecore